SL/No. Name Rate per unit Name and address of the firm Date of AT and date of received by this unit Specification Remarks
1. Inflatable Boat with OBM 326583.89 M/S Fibroplast, C- 30, Sector- 58, Noida, Gautam Budh Nagar, UP. procured by BSF 19/07/08 04 NOS 23/02/09

made mercury HP-25 RPM-5000-6000 The engine is electronic fuel injection system The engine cooling system shall be water cooled type with Thermostat The engine is Ultra low emission ratings The length of engine shaft is 15-20” The dry weight is more than 75 Kg The boat shall be inflatable with air pressure by foot pump The boat is suitable for 7-10 ( Seven to ten ) persons, or for 200 lbs weight The exterior size of the boat is min. 4200 mm x 1800 mm The interior size of the boat is min. 2925 mm x 1000 mm The diameter of the tube is 19” The air valves are one way type of approves type and make.. The weight of boat without floor board & OBM is more than 187 lbs. The boat is supplied with Bow storage bag and repair kit.

 
2. Fibre reinforced Plastic Boats 9 of 45 411534.64 M/S Poly Glass Fibre Industries Pvt Ltd, 265, Okhla Industrial Estate, New Delhi- 110020 procured by BSF 19/05/08 02 NOS 26/09/08 02 NOS 03/12/08 02 NOS 03/12/08 02 NOS 17/03/09 02 NOS 23/03/09

1. Make- Fibre Glass Rescue Boat- India 2. Brand- OBM- MARINER 40 HP Four Stroke ( USA ) 3 . The FRP Rescue boat is designed for carry 10 persons plus a crew of two, i.e a carriage capacity of 12 men or 1200 Kgs. The weight of the boat is within 350 Kgs excluding weight of OBM and Accessories. The free board at full load is not less than 12 inches. The length , width and height of the boat is not less than 1 5 feet, 6 feet and 2.5 respectively 4. The ignition system is Electronic Digital Inductive type 5. There has alternator of 18 Amp & 223 watts. The steering system is remote type with console at the front.

 
3. Portable Oxygen Breathing Unit 43, 312.5 M/S Udyogi Plastic (P) Limited, 294, B.B. Ganguly Street, 2n d floor, Kolkatta-12. Procured by SB Ftr BSF 18.08.08 (date of supply order) 02.12.08

Material have adequate mechanical strength, durability and resistance to detoriation by heat or by contact with sea water or plain water Parts are easy to clean, examination and testing Weight shall not exceed 14 kgs. Leak proof on joints Face mask is made up of either neopropane or silicon. Face mask cover eyes ,nose ,mouth and chin. Pressure gauge range 0-350 bars.

 
4. Motor Operated Multi cable winch 2,50,000 M/S Ageis Health Care, Suit No 1, Second Floor, Parmeshwari, Chhatribarib Road, Ghty Procured by CISF 15/06/09 16/02/10

The Multi cable winch should be required for small rescue work, the 4 to 5 hp rated motor, which should provide at least pulling power of 5 tons. It should have line retrieval speed not less than 6 meters/minutes at full pull. This compact winch shall complete with handle/mounting system for a class III two inch receiver, hawse, fairlead, remote control with minimum 3.6 meters, free spool clutch and battery cable with mounting kits.

 
5. Generator sets 2.5 KVA (Honda) 49799.50 M/s D R Brij Mohan & Sons Pvt ltd, G S Road, Bhangagarh Ghty ( Ph. No. 0361-2529416; 2529257 DGSND contract avail 31.08.07 (date of supply order) 03.09.07

Rated output -2100 -2300watt Max output- 2400-2600 Watt Fuel- kerosene/petrol Rated current- 10.5 amp Rated voltage- 220Volts Rated frequency- 50 Hz Dc output- 8.3 Amp Dimension- 605 x 425 x 550 mmDry wt- 60to65 kgs Engine type- 4 strokes, 1 cylinder Cooling system- forced air cooling Oil capacity- 1 to1.5 ltrs Fu el tank capacity- 12 to15 ltrs

 
6. High Pressure Pumps 229500/- M/s Inventa Cleantec Pvt Ltd, C-31, Sector-63 Noida-201301, Gautam Budhnagar, UP Procured by Prov Dte ( Proc Cell) FHQ, BSF  

Weight (filled and fuelled)- not more than 250 kg Tank capacity- 100 ltrs Water delivered- 23ltrs/min Nozzle pressure- 100 bar Range 10 mtr(solid stream) & 6 mtr( water mist) Length of hose- 60mtr Pump-rpm 1000 to 1500 Power of engine- 9.5 KW petrol driven

 
7. Rubber Suits 2672.00 M/s Joseph leslie & Co. Leslie House 3rd floor Proof V S Agshe Road off 87- C, Bhawani Shankar, Road, Dadar, West Mumbai Procured by Prov Dte ( Proc cell ) FHQ,BSF 14/08/07 28/12/07

1. Used for protection of the wearer against acid and alkali splashes in chemical, fertilizers and pharmaceutical material. 2. Made of high quality PVC

 
8. Tractor with attachments and trolley to be procured by Prov Dte ( Proc cell) to be procured by Prov Dte ( Proc cell) -

Not yet procured

 
9. Floating Pumps 119250.00 M/s Newage industrial 7, Champaklal Udyog Bhawan Sion (East) Mumbai- 22 Procured by Prov Dte ( Proc cell ) FHQ, CRPF 30/07/08 10/03/09

For the purpose of Fire Fighting and rescue operations. Light weight, reliable, self priming pump that floats, discharges water @ at least 180 ltr/ min. . Casing : anodized Aluminum . Impeller : Bronze impeller . Water resistant air cleaner and muffler. . 6 to 8 hp or more, air cooled. . Recoil starter with handle . Solid state ignition . Use unleaded gasoline/ Petrol and oil mixed . Minimum 2 years parts and service warranty . Automatic float controlled throttle . Compression release valve for easier starts Dry weight is not more than 30 Kgs.

 
10. Inflatable lighting tower 179168/- M/s Aska Equipments Limited, Aska House"œ Gargashraya” 193 Deepali, Deepali Chowk, Pitampura, New Delhi-34 DGS&D supply 25.06.07 30/07/07

Dimension-not more than 580x440x520mm Wt- 50 kg Total height-3-5 mtr Light source- 400watt Illuminating area- 10000 sq mtr Brightness- 4000 lumen Generator -4 stroke engine(petrol), capacity-1200 va Tank capacity- not less than 7 ltrs

 
11. Portable shelter 10' x 14' & 7' 144112.00 M/s Calcutta commercial corporation, 365 Sultanpur, Mehrauli- New Delhi Procured by DIG(P) Prov Compleas, Guwahati and supplied to this unit 11.06.08 12.08.08

1. The portable shelter should be easy to set up. 2. It is should be simplex, no framework and structure should be involved. The integral floor should set the dimensions of the shelter automatically on set up. Anchoring and guys will simply keep it in place during strong winds. 3. It should be lightweight so that 2 people can easily lift it. 4. Material should stay clean and dry and shall not absorb spills, improving hygiene. 5. Shelter walls open up from inside if fast escape shall be required. 6. The shelter should be totally weather resistant and keeps the occupants clean, dry and warm in high winds, cold temperatures, driving rain and heavy snow. 7. The rigid wall panels should be supported significant weight for organizing and storing the possessions of a family in temporary circumstance with hangers and shelves. 8. The double walled panel should be insulation at least"žR" factor of 1.4, allowing the shelter should be heated and cooled efficiently. 9. The while roof section should be allowed ample light transmission, giving the interior an airy and spacious atmosphere. 10. When lit from the inside at night, the maternal should be opaque enough to give privacy and the while interior allows efficient use of the light source. 11. Any flat panel should have a hole or flap cut into it by the occupant for exhaust ducting, water supply lines, drain pipes, extra ventilation etc. 12. The portable shelter should be repairable easily and permanently with duct tape. 13. Shelter should be moved with whole set up and with in tenor contents in place. This allows easy reorganization of established encampments if a road allowance needs to be widened or a drainage ditch needs to be widened or a drainage ditch needs to be constructed with a change in seasons. 14. The material used for the fabrication of shelter should be polypropylene. 15. The weight of the shelter (10" X 23" X 7") should not be more than 65 Kg.

 
12. Portable shelter 10'x23'x7' 2,08,000.00 M/s Calcutta commercial corporation, 365 Sultanpur, Mehrauli- New Delhi Procured by DIG(P) Prov Compleas, Guwahati and supplied to this unit 11.06.08 12.08.08

1. The portable shelter should be easy to set up. 2. It is should be simplex, no framework and structure should be involved. The integral floor should set the dimensions of the shelter automatically on set up. Anchoring and guys will simply keep it in place during strong winds. 3. It should be lightweight so that 2 people can easily lift it. 4. Material should stay clean and dry and shall not absorb spills, improving hygiene. 5. Shelter walls open up from inside if fast escape shall be required. 6. The shelter should be totally weather resistant and keeps the occupants clean, dry and warm in high winds, cold temperatures, driving rain and heavy snow. 7. The rigid wall panels should be supported significant weight for organizing and storing the possessions of a family in temporary circumstance with hangers and shelves. 8. The double walled panel should be insulation at least"žR" factor of 1.4, allowing the shelter should be heated and cooled efficiently. 9. The while roof section should be allowed ample light transmission, giving the interior an airy and spacious atmosphere. 10. When lit from the inside at night, the maternal should be opaque enough to give privacy and the while interior allows efficient use of the light source. 11.Any flat panel should have a hole or flap cut into it by the occupant for exhaust ducting, water supply lines, drain pipes, extra ventilation etc. 12.The portable shelter should be repairable easily and permanently with duct tape. 13. Shelter should be moved with whole set up and within tenor contents in place. This allows easy reorganization of established encampments if a road allowance needs to be widened or a drainage ditch needs to be widened or a drainage ditch needs to be constructed with a change in seasons. 14.The material used for the fabrication of shelter should be polypropylene. 15.The weight of the shelter (10" X 23" X 7") should not be more than 65 Kg. 16.

 